Connecting the RMX 4000 to the Power Sources
Connect the following power cables to the RMX 4000 back panel:
AC Power Supply connections:
1
Insert power cables to each of the three AC Power Entry Modules 
(PEMs).
Figure 2-2
RMX 4000 Rear Panel View with AC Power 
DC Power Supply connections: 
1
On the DC Power Rail Modules set the two circuit breakers to OFF.
2
Ensure that the cables from the Main that supplies electricity to the 
DC power units are OFF or disconnected.
3
Remove the transparent plastic caps on the terminal block.
The size of the protective earthing conductor & cable should be a minimum of 
10AWG.