1) 
Console Server Mode is the default and this enables general access to serial console port on the 
serially attached devices. 
2) 
Device Mode sets the serial port up to  communicate with an intelligent serial controlled PDU, 
UPS, or Environmental Monitor Device (EMD). 
3) 
SDT Mode enables graphical console access (with RDP, VNC, HTTPS, etc.) to hosts that are serially 
connected. 
4) 
Terminal Server Mode sets the serial port to wait for an incoming terminal login session. 
5) 
Serial Bridge Mode transparently interconnects two serial port devices over a network. 
 
 
Select Serial & Network: Serial Port and you will see the current labels, modes, logging levels, 
and RS-232 protocol options that are currently set up for each serial port. 
 
By default, each serial port is set in Console Server mode. To reconfigure the port, click Edit
 
When you have reconfigured the common settings (Chapter 4.1.1) and the mode (Chapters 4.1.2 
–4.1.6) for each port, you can set up any remote syslog (Chapter 4.1.7), then click Apply. 
Note 
If you want to set the same protocol options for multiple serial ports at once, click Edit Multiple 
Ports 
and select which ports you want to configure as a group. 
 
If the console server has been configured with distributed Nagios monitoring enabled, then you 
will also be presented with Nagios Settings options to enable nominated services on the Host to 
be monitored (refer Chapter 10—Nagios Integration). 
 
4.1.1  Common Settings  
There are a number of common settings that you can set for each serial port. These are independent of 
the mode in which the port is being used. Set these serial port parameters to match the serial port 
parameters on the device you attach to that port. 
_____________________________________________________________________ 
 
 
724-746-5500 | blackbox.com
 
 Page 47