Procedure
Step 1
Enable Quiet Mode in the BIOS policy of the server’s Service Profile.
Step 2
Establish a direct connection to the server, either by connecting a keyboard, monitor, and mouse to the front panel using
a KVM dongle (N20-BKVM) or by other means.
Step 3
Reboot the server.
Step 4
Press F2 during reboot to enter the BIOS setup screens.
Step 5
On the Advanced tab, select Trusted Computing and press Enter.
Step 6
Set the TPM Support option to Enable.
Step 7
Press F10 to save and exit. Allow the server to finish booting.
Server Troubleshooting
For general troubleshooting information, see the see the
Server Configuration
Cisco UCS blade servers are intended to be configured and managed using Cisco UCS Manager. For details, see the Configuration
Guide 
for the version of Cisco UCS Manager that you are using. The configuration guides are available at the following URL:
Physical Specifications for the Cisco UCS B200 M3
Value
Specification
1.95 inches (50 mm)
Height
8.00 inches (203 mm)
Width
24.4 inches (620 mm)
Depth
15.0 lbs (6.8 kg)
The system weight listed here is an estimate for a fully
configured system and will vary depending on peripheral
devices installed.
Weight