Mount the Topspin 270 Chassis in a Rack
This section describes how to install the Topspin 270 chassis in an equipment rack. The following 
procedure is the standard installation, using your own rack shelf. 
Topspin also has an optional shelf that is appropriate for pre-racking and shipping a unit in the rack. If 
you have purchased this shelf unit separately, refer to the documentation that is provided in the shelf kit 
package.
Requirements
In addition to the accessories provided with the server switch, you should have:
#2 phillips screwdriver
Rack with 6Us of available space
Shelf installed in the rack (not provided). The shelf must support the weight of the chassis, which 
can be up to 106 pounds with all possible components installed.
Screws appropriate to your rack, which are used to secure the rack handles to the rack posts. 
Three people are recommended to lift the switch into the rack; however, the procedure can be 
performed by two people. 
Note: The Topspin 270 chassis weighs up to 106 pounds (fully loaded).
Rack Mount Installation
To mount the Topspin 270 chassis in a rack:
1. Remove the CD-ROM, parts bag, and documentation from the box.
2. Remove the packaging from around the chassis.
3. Install a shelf for the chassis, if you have not already done so. Verify that the shelf can support the 
weight of the chassis, which can be up to 106 pounds with all possible components installed. 
Figure 2-1: Install Appropriate Rack in Shelf