Cisco Systems SFS 7008 Manual De Usuario

Descargar
Página de 108
86
Figure 5-21: Element Manager Sensors Tab
6. Note the OperStatus field. A status of “up” indicates that the sensor is functioning properly.
7. Note the Temperature field. Each slot has an individual temperature sensor. The Alarm and 
Shutdown temperatures vary by slot type. 
Monitor the System With the CLI
For a complete list of CLI commands, refer to the CLI Reference Guide
Use the following CLI commands to monitor the Power Supplies, the fans, and the sensors:
Monitor the Power Supplies
show power-supply
Example
Monitor the Fans
show  fan
An oper-status of “up” means that the blower is operating correctly within the fan unit. 
Topspin-270> show power-supply
================================================================================
                            Power-supply Information
================================================================================
ps    type    oper-status   utilization   voltage 
--------------------------------------------------------------------------------
1     AC      up            n/a           48      
2     AC      down          n/a           48      
================================================================================
                              Power-supply Seeprom
================================================================================
      product            pca                pca                fru              
ps    serial-number      serial-number      number             number           
--------------------------------------------------------------------------------
1     -                  -                  -                  -