Cisco Systems SFS 7008 Manual De Usuario

Descargar
Página de 108
90
Run Card Tests
References to “Cards” refers to fabric controllers, management I/O modules, node cards and the chassis 
ID module. Fans and power supplies are not included in the Card tests; they can be tested through the 
standard chassis test (
), or as individual components. 
The following tests are available to locate and diagnose one or more cards in the chassis:
LED 
Self-test 
Run a Card Self-Test
To perform a diagnostic self-test on a card:
1. Enter the diag card # command. 
You cannot stop the card test once it has begun. 
Example
2. Exit the test to view the progress of the test. 
The test takes approximately 5 - 8 minutes. 
Example of test in progress
Topspin-270> enable
Topspin-270# config
Topspin-270(config)# diag card 11 
Topspin-270(config-diag-card-11)# test self-test
Topspin-270(config-diag-card-11)# start
Topspin-270(config-diag-card-11)# exit
Topspin-270(config)# exit
Topspin-270# show diagnostic card 11
================================================================================
                           Diagnostic Tests For Cards
================================================================================
                     test : self-test
                  slot-id : 11
               iterations : 1
                   action : start
                   result : In progress
     percentage-completed : 0
            result-string :