4. Use the show diag fru-error command to display any errors that appear in the result-string. 
Example
5. Reboot the chassis when the self-test is complete. 
Example
Run Power Supply Tests
The following tests are available to locate and diagnose fan modules:
LED 
Self-Test 
Run a LED Test on the Power Supply
Use the LED test to blink the LED and identify a specific power supply. 
Example
Topspin-270# show diag fru-error
============================================================
                                   Fru-Error
============================================================
fru-slot        fru-error
------------------------------------------------------------
card(1)         none
card(2)         none
card(7)         none
card(8)         none
card(9)         none
card(10)        none
card(11)        none
card(12)        none
card(13)        none
card(14)        none
card(15)        none
card(17)        none
fan(1)          none
fan(2)          none
Topspin-270# reload
System configuration is modified. Save? [yes(default) | no | filename] y
Proceed with reload? [yes(default) | no] y
Topspin-270> enable
Topspin-270# config 
Topspin-270(config)# diag power-supply 1
Topspin-270(config-diag-power-supply-1)# test led
Topspin-270(config-diag-power-supply-1)# start
Topspin-270(config-diag-power-supply-1)# stop
Topspin-270(config-diag-power-supply-1)#