Cisco Systems SFS 7008 Manual De Usuario

Descargar
Página de 108
99
Displaying Hardware Errors
To display POST results, non-fatal errors that can are recovered, informational logging (such as 
firmware updates), and hardware errors:
1. Use the more syslog:hwif_log command to locate the:
/topspin/log/hwif_log 
Example of output without errors
You can also view POST error codes with the show diagnostic post command. This command displays 
the results of each POST that executed at power-on.
Example
Topspin-270> enable
Topspin-270# more syslog:hwif_log
Thu Mar  4 10:57:49 2004: POST: SEEPROM: PASSED
Thu Mar  4 10:57:49 2004: POST: FPGA: PASSED
Thu Mar  4 10:57:49 2004: POST: SUMMIT: PASSED
Thu Mar  4 10:57:50 2004: POST: RTC: PASSED
Thu Mar  4 10:57:54 2004: POST: FAN: PASSED
Thu Mar  4 10:57:54 2004: card_startup.x : card is starting up
Thu Mar  4 10:57:54 2004: Anafa2Init: a2update set to IGNORE
Thu Mar  4 10:58:16 2004: Anafa2 POST: firmware check PASSED
Thu Mar  4 19:01:55 2004: POST: SEEPROM: PASSED
Thu Mar  4 19:01:55 2004: POST: FPGA: PASSED
Thu Mar  4 19:01:55 2004: POST: SUMMIT: PASSED
Thu Mar  4 19:01:56 2004: POST: RTC: PASSED
Thu Mar  4 19:02:00 2004: POST: FAN: PASSED
Thu Mar  4 19:02:00 2004: card_startup.x : card is starting up
Thu Mar  4 19:02:00 2004: Anafa2Init: a2update set to IGNORE
<output truncated>
Topspin-270# show diagnostic post
================================================================================
                                  Post Status
================================================================================
fru-slot        post-status     error-codes
--------------------------------------------------------------------------------
card(1)         failed          1:0:0:0
fan(1)          passed          0:0:0:0
fan(2)          passed          0:0:0:0
power-supply(1) passed          0:0:0:0