Setup & Operation    5. Motion Range 
 
G10 / G20 Rev.2 
59 
 
5.1.2    Max. Pulse Range of Joint #2 
The 0 (zero) pulse position of Joint #2 is the position where Arm #2 is in-line with Arm #1.   
With the 0 pulse as a starting point, the counterclockwise pulse value is defined as the 
positive (+) and the clockwise pulse value is defined as the negative (-). 
 
0 pulse 
 
 
 
Model 
Table Top Mounting  Ceiling / Wall Mountings
G10-65*S* 
±130 degrees 
G10 / G20-85*S* 
±152.5 degrees 
Z: 0 to 
−360 
±152.5 degrees 
G10 / G20-85*C* 
Z: 
360 to 
390 
±151 degrees 
±151 degrees 
Max. Motion 
Range 
G20-A0*S* 
±152.5 degrees 
±152.5 degrees 
G10-65*S* 
±2366578 
G10 / G20-85*S* 
±2776178 
Z: 0 to 
−360 
±2776178
 
G10 / G20-85*C* 
Z: 
360 to 
390 
±2748871 
±2748871 
Max. Pulse 
Range 
G20-A0*S* 
±2776178
 
±2776178
 
 
)
NOTE
 
In the range Z: –360 to –390 mm, the area is limited by interference of the Manipulator body and the arm.