Emerson Surge and Signal Protection Manual De Usuario

Descargar
Página de 4
Model
Configuration
Surge Current Capability (kAmps)
Dimensions* (inches)
Phase 
L-G 
L-L
L-N
N-G
H x W x D
H1/H2xxxS111   
Split Single Phase
250
125
125 
125
20 x 16 x 9
3 wire and ground
H1/H2xxxY111
Three Phase Wye
250
125
125
125
20 x 16 x 9
H1/H2xxxD110
Three Phase Delta
250
125
125
20 x 16 x 9
3 wire and ground
H1/H2xxxH111
Three Phase Delta
250 
125 
125
125
20 x 16 x 9
Hi-Leg, 4 wire and ground
H1/H2xxxS222
Split Single Phase 
320 
160 
160 
160
24 x 20 x 9
3 wire and ground
H1/H2xxxY222
Three Phase Wye 
320 
160 
160 
160
24 x 20 x 9
4 wire and ground
H1/H2xxxD220
Three Phase Delta 
320 
160 
160
24 x 20 x 9
3 wire and ground
H1/H2xxxH222
Three Phase Delta 
320 
160 
160 
160
24 x 20 x 9
Hi-Leg 4 wire and ground
Split Single Phase, 3 Wire plus Ground
120/240
Three Phase Wye, 4 Wire plus Ground
120/208, 230/400, 277/480
Three Phase Delta, 3 Wire plus Ground
208, 240, 400, 480
Three Phase Delta Hi-Leg, 4 Wire plus Ground
120/240
At a Glance
n
Unique "Surge Current Transition
Circuit" allows for seamless
transition from primary (SAD
technology) to secondary 
(MOV array technology)
suppression system. A true,
shared suppression system.
n
Industry’s only Active Disconnect
System protects against system
failure and degradation due to
overvoltages.
n
Lowest UL 1449 clamping voltages
achieved—330VAC line to neutral
for a 120/208V Wye unit.
n
Technology of choice for speed,
allowing picosecond response time.
n
All surge suppression components
used are computer tested and
matched. SAD’s are matched to +/-
1% and MOVs are matched to 1 volt
for optimum reliability and long life.
n
Matched low impedance buss
system for both SAD and MOV
modules.
n
Liebert Hybrid Advantage builds
upon industry standard
Interceptor® Series design. Unique
benefits include:
— Patented component level
monitoring — including neutral 
to ground.
— Unique sand-packed silver fuse
network UL Rated at 300kAIC 
for safety.
— Highest surge current capability
and survivability in the industry.
— 10-year warranty on parts and 
5-year on-site labor, backed by
Emerson Power Service.
3
Liebert Hybrid Advantage Models 
Medium Exposure Units
(250kAmp and 320kAmp current capacity units)
Nominal Voltage Codes
(substitute for xxx to complete model number)
Note: For other voltage configurations not listed, please consult factory.
The Liebert Hybrid Advantage features 
the fast response time of the Silicone
Avalanche Diode (SAD).
SAD Surge Energy
250J
2 500J
L-N Voltage
120  120V
208 208V
230  230V
240  240V
277 277V
480  480V
Configuration
N
Single Phase L-N
L
Single Phase L-L
S
Split Phase
Y
3 Phase Wye
D
3 Phase Delta
H
3 Phase Hi-Leg
Monitoring Options
01 
LED
04 LED, 
Alarm
05 
LED, Surge
Counter
06 LED, 
Alarm, 
Surge Counter
03
LED, Alarm, Dual 
Surge Counters
Connection Type
“blank”
Compression
Lugs
R
Rotary
Disconnect
Specif ying The Appropriate Model
All model numbers begin with a prefix. Use Chart A to build your Liebert Hybrid
Advantage starting with the SAD Surge Energy column. Moving left to right, choose the
correct configuration from each column for your application. Your completed model
number should look similar to the example below:
Example Part Number:
H   2 1 2 0 Y 4 4 4 R -   0 3
Chart A
Surge Current Rating
111 
250kA Per Phase
222 
320kA Per Phase
333 
400kA Per Phase
444 
750kA Per Phase
Model
Configuration
Surge Current Capability (kAmps)
Dimensions* (inches)
Phase 
L-G 
L-L
L-N
N-G
H x W x D
H1/H2xxxS333   
Split Single Phase
400
200
200 
200
24 x 24 x 9
3 wire and ground
H1/H2xxxY333
Three Phase Wye
400
200
200
200
24 x 24 x 9
4 wire and ground
H1/H2xxxD330
Three Phase Delta
400
200
200
24 x 24 x 9
4 wire and ground
H1/H2xxxH333
Three Phase Delta
400 
200 
200 
200
24 x 24 x 9
Hi-Leg, 4 wire and ground
H1/H2xxxS444
Split Single Phase 
750 
375 
375 
375
30x 24 x 9
3 wire and ground
H1/H2xxxY444
Three Phase Wye 
750 
375 
375 
375
30x 24 x 9
4 wire and ground
H1/H2xxxD440
Three Phase Delta 
750 
375 
375
30x 24 x 9
3 wire and ground
H1/H2xxxH444
Three Phase Delta 
750 
375 
375 
375
30x 24 x 9
Hi-Leg 4 wire and ground
High Exposure Units 
(400kAmp and 750kAmp current capacity units)
*Optional Disconnect Doesn’t Change Dimensions