Motorola DS3478 Manual De Usuario

Descargar
Página de 404
7 - 10 Symbol DS3478 Product Reference Guide
Check Receive Errors
Select whether or not to check the parity, framing, and overrun of received characters. The parity value of received 
characters is verified against the parity parameter selected previously.
Stop Bit Select
The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and 
prepares the receiving device for the next character in the serial data stream. Select the number of stop bits (one or 
two) based on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to 
match host device requirements.
*
Check For Received Errors 
(Enable)
Do Not Check For Received Errors 
(Disable)
*
1 Stop Bit
2 Stop Bits