4 - 10 Symbol DS6707 Digital Imager Scanner Product Reference Guide
Decode Session Timeout
Parameter # 88h
This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 
0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds.
To set a Decode Session Timeout, scan the bar code below. Next, scan two numeric bar codes from 
 that correspond to the desired on time. Enter a leading zero for single digit numbers. For 
example, to set a Decode Session Timeout of 0.5 seconds, scan the bar code below, then scan the 0 and 5 bar 
codes. To correct an error or change the selection, scan Cancel on 
Timeout Between Decodes, Same Symbol
Parameter # 89h
Use this option in presentation (hands-free) mode to prevent the beeper from continuously beeping when a symbol 
is left in the digital imager scanner’s field of view. It is programmable in 0.1 second increments from 0.0 to 9.9 
seconds. The default interval is 0.6 seconds. 
To select the timeout between decodes for the same symbol, scan the bar code below, then scan two numeric bar 
codes from 
 that correspond to the desired interval, in 0.1 second increments.
Decode Session Timeout