Motorola DS6707 Manual De Usuario

Descargar
Página de 402
5 - 2
Symbol DS6707 Digital Imager Scanner Product Reference Guide
Scanning Sequence Examples
In most cases scanning one bar code sets the parameter value. For example, to disable the decode aiming pattern, 
scan the Disable Decode Aiming Pattern bar code under 
. The digital 
imager scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry.
Other parameters require scanning several bar codes. See these parameter descriptions for this procedure.
Errors While Scanning
Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
Imaging Preferences Parameter Defaults
 lists the defaults for imaging preferences parameters. There are two ways to change the default values:
Scan the appropriate bar codes in this guide. These new values replace the standard default values in 
memory. To recall the default parameter values, scan the 
Download data through the device’s serial port using SSI. Hexadecimal parameter numbers appear in this 
chapter below the parameter title, and options appear in parenthesis beneath the accompanying bar codes. 
See the Simple Serial Interface (SSI) Programmer’s Guide for detailed instructions for changing parameters 
using this method.
NOTE
See 
 for all user preferences, hosts, symbologies, and 
miscellaneous default parameters.
Table 5-1    
 Imaging Preferences Parameter Defaults
Parameter
Parameter 
Number
Default
Page 
Number
Imaging Preferences
Operational Modes
N/A
N/A
Low Light Enhancement
F1h 64h
Disable
Presentation Mode Field of View
F1h 61h
Default (Reduced)
Image Capture Autoexposure
F0h 68h
Enable
Image Capture Illumination
F0h 69h
Enable
Illumination Bank Control
F1h 3Bh
Full
Fixed Exposure
F4h F1h 37h
100
Fixed Gain
F1h 38h
50
Gain / Exposure Priority for Snapshot Mode
F1h 32h
Autodetect
Snapshot Mode Timeout
F0h 43h
0 (30 seconds)