Manual No. 25-ULPNR102-01; Mar, 2005                                   LMD 1135 Laser Fixed Mount Scanner 
Page  1 
Section 1
 
 
Introduction and Getting Started
  
Product Overview 
The LMD 1135 Fixed Position Scanner is a miniature, 100 scan per second, laser bar code reader 
designed to be easily incorporated into host equipment.  The small physical size makes the scanner easy 
to integrate into any hardware design.  Durability and reliability are assured.   
Advanced microprocessor technology coupled with Opticon’s proven decoding algorithms result in high 
speed operation with superior accuracy.  The scanner is fully programmable allowing the user to 
customize parameters including changing communication settings, selecting symbologies, adding prefixes 
and appending suffixes.   Programmable settings can be downloaded from the host CPU or computer 
directly to the scanner.    
The scanner is encased in a compact, rugged, yet lightweight-plastic enclosure.  The compact size 
permits installation in the tightest areas allowing great flexibility in mounting and positioning the scanner 
for optimum performance. 
Quick Start-Up Procedure 
This section is for those who wish to start using the scanner before reading the complete manual.  In 
only a few steps the scanner will be operable. 
Turn off the power to your PC and connect the scanner to an RS232 communications port.   Note:  You 
must provide +5 Volt DC power to the scanner.  If you are using our standard LPN1137RR1S-050 or have 
purchased the evaluation kit, you can utilize power supply, P/N 32-00907-01, by plugging its connector 
directly into the pigtail connector on the scanner.  If the power supply is obtained from another source 
verify that it is identified with the 
CE 
mark.  Turn on the power to the PC. 
1)  Using communications software (e.g., Procom), set the communication parameters: 9600 baud, 
1 Start/Stop Bit,  8 Data Bits, No Parity, No Handshaking,  No Flow Control 
2)  If you are operating in a Microsoft Windows 3.1 environment, skip to Step 5. 
3)  If you are operating in a Microsoft Windows 95/98/ 2000/ XP environment, you can set the 
communication parameters using Hyper Terminal as follows: 
♦ 
Open Hyper Terminal.  This can be done from Start
→Programs→Accessories/ 
Communications 
♦ 
Select Hypertrm.exe to create a New Connection 
♦ 
In the Connection Description dialog screen enter a name for the new file.  If desired, select 
an Icon.  Click OK 
♦ 
In the 
Connect To
 (
Phone Number)
 dialog screen, in the box entitled: 
Connect using
. select 
the communication port, for example, “Direct to Com 1” Click OK 
♦ 
In the 
Com 1 Properties
 screen, enter the appropriate Port Settings:  Bits per second = 9600,  
Data bits = 8,  Parity = None,  Stop Character = 1, Handshaking = None, Click OK 
♦ 
The hyper-terminal folder you just created will open.  From the File pull-down menu, select 
Properties
  then click on the 
Setting
 Tab