GenTran 5.1 Manual De Usuario

Descargar
Página de 408
Inbound Interchange Entry Dialog Box
Using Partners
Gentran:Server for Windows – November 2005
Gentran:Server for Windows User’s Guide
3 - 32
Parts and
functions
The following lists the parts of the Inbound Interchange Entry dialog box and their 
functions: 
Part
Function
Description
Contains the name of the interchange description.
Standard
Displays the EDI standard the system is using for this 
relationship definition.
Version
Displays the version of the EDI standard the system is 
using for this relationship.
Interchange ID
Select the type of interchange. The standard defines which 
interchange ID should be used with each standard. This is a 
mandatory box.
Example
ANSI X12 - ISA
- ICS
UCS
- BG
EDIFACT
- UNB
Tradacoms - STX
Sequence 
Checking
Specify if the system will use sequence checking and 
whether the sequence checking will be incremental or 
chronological. You can also indicate that the system must 
check for duplicate control numbers.
None
Do not use sequence checking.
Duplicate
Check for duplicate control numbers.
Incremental
The control number must be one 
greater than the last number.
Chronological The control number must be greater 
than the last number.
Note
If the system detects duplicate control numbers or detects 
incremental or chronological control numbers that are out 
of sequence, those documents will be put in the ?In 
Documents.
(Continued on next page)