                                User Guide for Polycom® RMX™ 500 and Polycom® RMX™1000 Systems 
                                                                              (Conference on Ports)   
   
 
 
 
18-7 
[Example 2] Set the 100M half duplex for the LAN 1 interface: 
 
 
After you set the connection feature or IP address for the LAN interface, the system 
must be restarted in order for the new settings to take effect. 
 
Password Checking   
Key in "password checking {on| off}" after the prompt "#" to enable or disable 
the password checking function.   
When password checking are enabled and you are setting a user password on 
the Web page, you must enter a password consisting of letters, numbers and 
special characters (~` ! @ # $ ^ * ( )_- [ ] ; : , . / ?), with a length of 8-40 
characters.   
Password Encryption   
Key in "password encryption {on| off}" after the prompt "#" to enable or 
disable the password encryption function.   
When password encryption is enabled and a user is logging into the Web 
configuration page, the system will use a more complex encryption algorithm 
for the entered login password to ensure the security of this 
network-transmitted password, and at the same time, the system will use the 
HTTPS protocol to establish an SSL security connection with the client. In this 
mode, when a user enters his/her username and password and click Login, 
the user may be prompted that this website has been blocked or the security 
certificate has expired based on the currently-used IE browser's version. In 
order to enter the system, the user must allow the website contents to be 
displayed and re-enter his/her login information when prompted. If high 
security requirement is not necessary, we recommend that you disable this 
function.   
Set I-frame Timing Interval   
Key in "iframe timing interval {value}" after the prompt "#" to set the timing 
interval for an endpoint to launch an I-frame request.   
Parameters Description 
Parameter 
Description 
value
 
Time interval, 10 seconds by default, with a 
modification range of 10 – 300 seconds.