Cisco Systems 3750E Manual De Usuario

Descargar
Página de 1236
 
45-13
Catalyst 3750-E and 3560-E Switch Software Configuration Guide
OL-9775-02
Chapter 45      Troubleshooting
Recovering from Lost Cluster Member Connectivity
Recovering from Lost Cluster Member Connectivity
Some configurations can prevent the command switch from maintaining contact with member switches. 
If you are unable to maintain management contact with a member, and the member switch is forwarding 
packets normally, check for these conflicts:
A member switch (Catalyst 3750-E, Catalyst 3750, Catalyst 3560-E, Catalyst 3560, Catalyst 3550, 
Catalyst 3500 XL, Catalyst 2970, Catalyst 2960, CGESM, Catalyst 2950, Catalyst 2900 XL, 
Catalyst 2820, and Catalyst 1900 switch) cannot connect to the command switch through a port that 
is defined as a network port.
Catalyst 3500 XL, Catalyst 2900 XL, Catalyst 2820, and Catalyst 1900 member switches must 
connect to the command switch through a port that belongs to the same management VLAN.
A member switch (Catalyst 3750-E, Catalyst 3750, Catalyst 3560-E, Catalyst 3560, Catalyst 3550, 
Catalyst 2970, Catalyst 2960, CGESM, Catalyst 2950, Catalyst 3500 XL, Catalyst 2900 XL, 
Catalyst 2820, and Catalyst 1900 switch) connected to the command switch through a secured port 
can lose connectivity if the port is disabled because of a security violation.
Preventing Autonegotiation Mismatches
The IEEE 802.3ab autonegotiation protocol manages the switch settings for speed (10 Mb/s, 100 Mb/s, 
and 1000 Mb/s, excluding SFP module ports) and duplex (half or full). There are situations when this 
protocol can incorrectly align these settings, reducing performance. A mismatch occurs under these 
circumstances:
A manually set speed or duplex parameter is different from the manually set speed or duplex 
parameter on the connected port.
A port is set to autonegotiate, and the connected port is set to full duplex with no autonegotiation.
To maximize switch performance and ensure a link, follow one of these guidelines when changing the 
settings for duplex and speed:
Let both ports autonegotiate both speed and duplex.
Manually set the speed and duplex parameters for the ports on both ends of the connection.
Note
If a remote device does not autonegotiate, configure the duplex settings on the two ports to match. The 
speed parameter can adjust itself even if the connected port does not autonegotiate.
Troubleshooting Power over Ethernet Switch Ports
These sections describe how to troubleshoot Power over Ethernet (PoE) ports.