Cisco Systems 3750E Manual De Usuario

Descargar
Página de 1236
 
45-27
Catalyst 3750-E and 3560-E Switch Software Configuration Guide
OL-9775-02
Chapter 45      Troubleshooting
Using On-Board Failure Logging
Power over Ethernet (PoE)—Record of the power consumption of PoE ports on a standalone switch 
or a stack member
Temperature—Temperature of a standalone switch or a switch stack member
Uptime data—Time when a standalone switch or stack member starts, the reason the switch restarts, 
and the length of time the switch has been running since it last restarted
Voltage—System voltages of a standalone switch or a stack member
You should manually set the system clock or configure it by using Network Time Protocol (NTP). 
When the switch is running, you can retrieve the OBFL data by using the show logging onboard 
privileged EXEC commands. If the switch fails, contact your Cisco technical support representative to 
find out how to retrieve the data.
Note
OBFL is supported only on Catalyst 3750-E and 3560-E switches. It is not supported on Catalyst 3750 
and 3560 switches. 
Configuring OBFL
To enable OBFL, use the hw-module module [switch-numberlogging onboard [message level level
global configuration command. On Catalyst 3750-E switches, the range for switch-number is from 1 
to 9. On Catalyst 3560-E switches, the switch number is always 1. Use the message level level parameter 
to specify the severity of the hardware-related messages that the switch generates and stores in the flash 
memory.
Caution
We recommend that you do not disable OBFL and that you do not remove the data stored in the flash 
memory.
To disable OBFL, use the no hw-module module [switch-numberlogging onboard [message level
global configuration command.
To clear all the OBFL data in the flash memory except for the uptime and CLI command information, 
use the clear logging onboard privileged EXEC command.
In a switch stack, you can enable OBFL on a standalone switch or on all stack members by using the 
hw-module module logging onboard [message level level] global configuration command. 
In a switch stack, if you enter the hw-module module [switch-numberlogging onboard command on 
a stack member that does not support OBFL, such as a Catalyst 3750 switch, a message appears with that 
information. If a Catalyst 3750 switch is a stack master in a mixed stack of Catalyst 3750-E and 3750 
switches and you enter an OBFL command on the Catalyst 3750 switch, the command does not take 
effect on the stack master, but the stack master sends the OBFL configuration information to the stack 
members.
For more information about the commands in this section, see the command reference for this release.