K. Bin Control Check
An infrared sensor is used as the primary bin control to control the level of ice in the 
dispensing unit/storage bin. A mechanical bin control is used as a backup bin control.
IMPORTANT
1. Make sure the icemaker has been installed as outlined in this manual and 
that the water supply is on.
. Make sure S1 Dip Switch 7 is in the "ON" position. This allows the control 
board to monitor the infrared sensor along with the mechanical backup bin 
control.
1. Infrared Sensor Check
1) Turn off the power supply.
) Remove the front panel, top panel, and control box cover.
3) Confirm that control board S1 dip switch 1, , and 3 are in the proper position for your 
application. "See IV.K.3. Infrared Sensor Shutdown Delay." 
4) Move the control switch on the control box to the "ICE" position, then move the power 
switch to the "ON" position.
5) Turn on the power supply to start the automatic icemaking process. The green LED on 
the infrared sensor turns on. This LED confirms 0V DC power to the sensor.
6) Make sure the "GM" LED on the control board is on. See Fig. 17. There is a delay of 
at least 30 seconds before the "GM" LED turns on after power-up. After the "GM" LED 
turns on, press the "SERVICE" button on the control board to bypass the 5-minute 
compressor delay. 
WARNING! Risk of electric shock. Care should be taken not to 
touch live terminals. The "COMP" LED turns on.
"SERVICE" 
Button
S1 Dip Switch
"GM" LED
"COMP" LED
K
6 - Connector for 
Infrared Sensor
Fig. 17