Videk 2030 Manual De Usuario

Descargar
Página de 98
K11020 VisionSensor™ 2030 User Manual, Rev. E, Software ver. 3.1.1000, August 3, 2007    -    
45
Save Settings
5.2 - Set Targeting Zone Tolerances
50 
Most Accurate 
 
75 
 
 
 
00   
 
 
25
50   
 
200   
 
 
400   
 
 
600  
(Default)
 
 
 
 
 
 
 
 
 
 
 
 
Least Accurate
The targeting zone is the area around the outside of the code that is viewed by the imager. The values 
of each of the following codes are the pixels extending from the outside of the edge of the symbol being 
scanned. As the targeting zone becomes smaller the targeting laser must be more centered in the sym-
bol being scanned. Conversely, as the targeting area outside the code gets larger there is less precision 
needed with the targeting laser. There is also a greater chance the imager will have more than one code in 
the field of view. The symbol in focus, closest to the targeting laser will be decoded.
5. - Continuous Illumination
Scan one of the following codes to enable continuous LED illumination.
Enable Continuous Illumination   
 
Disable Continuous Illumination (Default)
Note: Videk recommends only using this feature with cabled units due to increased power consumption.