Cooling Subsystem 
Intel® Server System SR2500AL 
 
 
Revision – 1.00 
Intel order number D31980-004 
22 
•  Each fan has an associated fault LED on the mid-plane located next to the fan header.  
In the event of a fan failure, the fault LED for the failing fan can be illuminated by system 
management.  
 
Table 14.  Non-redundant Fan Connector Pin Assingment 
Pin 
Signal Name 
Description 
1 Tachometer 
Reserved, 
unused by the non-redundant fan 
PWM 
Fan speed control signal 
12V 
Power for fan 
12V 
Power for fan 
Tachometer A 
Fan RPM sensor output 
Two pulse per revolution for the 80mm fan 
Four pulses per revolution for the 60mm fan 
Return 
Return path to ground 
Return 
Return path to ground 
8 Fan 
Presence 
Reserved, 
unused by the non-redundant fan 
LED Cathode 
Loopback signal to pin 10 
10 
LED Anode 
Loopback signal to pin 9 
The system fans plug into headers on the mid-plane board according to the following diagram. 
2
1
3
 