Cisco 4400 Series WLAN Controller AC Power Supply (redundant) AIR-PWR-4400-AC= Hoja De Datos

Los códigos de productos
AIR-PWR-4400-AC=
Descargar
Página de 4
 
 
Data Sheet 
All contents are Copyright © 1992–2007 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. 
Page 3 of 4 
Item 
Specification 
Management 
  SNMP v1, v2c, v3 
  RFC 854 Telnet 
  RFC 1155 Management Information for TCP/IP-Based Internets 
  RFC 1156 MIB 
  RFC 1157 SNMP 
  RFC 1213 SNMP MIB II 
  RFC 1350 TFTP 
  RFC 1643 Ethernet MIB 
  RFC 2030 SNTP 
  RFC 2616 HTTP 
  RFC 2665 Ethernet-Like Interface types MIB 
  RFC 2674 Definitions of Managed Objects for Bridges with Traffic Classes, 
Multicast Filtering, and Virtual LAN Extensions 
  RFC 2819 RMON MIB 
  RFC 2863 Interfaces Group MIB 
  RFC 3164 Syslog 
  RFC 3414 User-Based Security Model (USM) for SNMPv3 
  RFC 3418 MIB for SNMP 
  RFC 3636 Definitions of Managed Objects for IEEE 802.3 MAUs 
  Cisco private MIBs 
Management Interfaces 
  Web-based: HTTP/HTTPS 
  Command-line interface: Telnet, SSH, serial port 
Interfaces and Indicators 
  Uplink: 2 (4402) or 4 (4404) 1000Base-X transceiver slots 
  LED indicators: link, activity 
  Service Port: 10/100 Mbps Ethernet (RJ45) 
  LED indicators: link, activity 
  Utility Port: 10/100/1000 Mbps Ethernet (RJ45) 
  LED indicators: link, activity 
  Expansion Slots: 1 (4402) or 2 (4404) 
  Console Port: RS232 (DB-9 male, DTE interface) 
  Other Indicators: Status, Alarm, Power Supply 1, Power Supply 2 
Physical and Environmental 
  Dimensions (WxDxH): 17.45 x 15.75 x 1.75 in. (443 x 400 x 44.5 mm) 
  Weight: 15.3 lbs (6.95 kg) with 2 power supplies 
  Temperature: 
  Operating: 32 to 104°F (0 to 40°C) 
  Storage: -13 to 158°F (-25 to 70°C) 
  Humidity: 
  Operating humidity: 10 95%, non-condensing 
  Storage humidity: up to 95% 
  Input power: 100 240 VAC; 50/60 Hz; 0.43 A at 110 VAC, 0.23 A at 220 VAC; 
50W. Redundant power option available. 
  Heat Dissipation: 171 BTU/hour 
Regulatory Compliance 
  CE Mark 
  Safety: 
  UL 60950-1:2003 
  EN 60950:2000 
  EMI and susceptibility (Class A): 
  U.S.: FCC Part 15.107 and 15.109 
  Canada: ICES-003 
  Japan: VCCI 
  Europe: EN 55022, EN 55024