Graco 258849 Manual De Usuario

Descargar
Página de 28
Repair Kit 
18
3A1456D
Repair Kit
Outlet Valve Fitting
NOTE: Before doing any repair to pump, perform 
Flushing Sprayer procedure, page 14.
Removal
1.
Engage trigger lock and pull relief valve UP to 
release pressure.
2.
Remove battery.
3.
Remove pump outlet cap.
4.
Use tool (supplied) to loosen and remove outlet 
valve fitting.
Installation
1.
Screw outlet valve fitting into threads. Use tool (sup-
plied) and tighten to 8 ft-lb (11 N•m).
2.
Press new pump outlet cap into place.
ti14994a
ti14999a
ti14996a
ti15503a
ti15506a
ti15508a
ti15507a