Graco 254973 Manual De Usuario

Descargar
Página de 20
Troubleshooting 
14
311771E
Troubleshooting
Problem
Cause
Solution
Sprayer won’t run
Power switch not on
Turn switch on.
No power at wall outlet
Check outlet by seeing if light in the 
plug is illuminated. If not, try another 
outlet.
Wrong size generator
Use a 3500 watt or larger generator. 
Refer to Generator Requirements, 
page 6.
Too many items on same circuit
Unplug other items from circuit
Extension cord too long or wrong 
gauge
Use a different extension cord. Refer 
to Grounding and Electric Require-
ments, page 6.
Breaker tripped
Reset breaker.
Blown motor fuse
Check to see if fuse needs to be 
replaced, page 12.
Pump won’t pump material
Failed motor or motor shield 
Replace motor or motor fuse.
Mix too thick
Add water to thin material. Use Mate-
rial Thickness Gauge.
Plugged gun
Relieve Pressure, page 6. Remove 
gun from hose. Clean gun.
RotoFlex II pump worn out
Replace hose. Recommended hose 
replacement - once a year or every 
3000 gallons.
Pump cold or material frozen in pump Move pump to warm room and allow 
it to warm up or run hot water through 
sprayer.
Material in hose
Remove material hose from outlet 
and run until material flows.
Material runs out of bottom of sprayer 
onto floor
RotoFlex II pump worn out
Replace hose.
No air flowing from gun
Gun air valve closed
Open gun air valve.
Gun needle plugged
Clean needle and retry.
Lines not connected
Check all connections to gun and 
hoses.
Damaged hose
Replace hose.
Worn compressor
Replace compressor.