Installation
312900G
11
Connect the Air Line
1.
Connect the Graco Grounded Air Supply Hose (R) 
between the air supply line and the gun's air inlet (V) 
(F
. 2). The gun air inlet fitting has a left-hand 
thread. Connect the air supply hose ground wire (Q) 
to a true earth ground.
2.
Install an air line filter/water separator (O) on the 
gun air line to ensure a dry, clean air supply to the 
gun. Dirt and moisture can ruin the appearance of 
your finished workpiece and can cause the gun to 
malfunction.
3.
Install a bleed-type air regulator (G) on the pump 
and gun air supply lines to control air pressure to the 
pump and gun.
4.
Install a bleed-type air valve (E) on the pump air line 
to shut off air to the pump. Install an additional 
bleed-type air valve (C) on the main air line (A) to 
isolate the accessories for servicing.
5.
Install an air shutoff valve (P) on each gun air supply 
line to shut off air to the gun(s).
Connect the Charging Probe
1.
Apply dielectric grease to probe socket.
2.
Press electrode on in Connect/Disconnect position 
shown in F
IG
. 4.
3.
Rotate electrode to spray position.
F
IG
. 4
To reduce the risk of electric shock or other serious 
injury, the air supply hose must be electrically con-
nected to a true earth ground. Use only Graco 
Grounded Air Supply Hose.
F
IG
. 2
The bleed-type air valve (E) is required in your sys-
tem to relieve air trapped between the valve and the 
pump after the air regulator is shut off. Trapped air 
can cause the pump to cycle unexpectedly, which 
can result in serious injury, including splashing fluid 
in the eyes or on the skin.
ti1259a
R
V
Q
To air supply
ti1259
F
IG
. 3
NOTICE
The external charging probe rotates easily. Do not 
press too hard when rotating it or it could be dam-
aged.
NOTICE
For proper performance, do not operate electro-
statics if the charging probe is not in spray position.
Probe
Socket 
ti12722
ti1933a
Connect/Disconnect 
Position
Connect the Charging Electrode
Position
Spray