Operation
310692C
13
Operation
Pressure Relief Procedure
1.
Turn off air and fluid supply.
2.
Hold a metal part of the gun firmly to a grounded 
metal pail. Trigger the gun to relieve pressure.
Applying the Fluid
When using the HVLP spray gun, instead of a conven-
tional airspray gun, you may need to use a slightly 
slower hand movement and make fewer passes with the 
gun to coat a part. This is due to the reduced spray 
velocity produced by lower HVLP air pressures, along 
with a larger fluid particle size because there is less air 
to blow off solvents than what is produced by conven-
tional airspray. Take care to avoid runs or sags as you 
spray.
1.
To achieve the best results when applying fluid:
Keep the gun perpendicular and 6 to 8 inches 
(150 to 200 mm) from the object being sprayed.
Use smooth, parallel strokes across the surface 
to be sprayed with 50% overlap. 
WARNING
Follow Pressure Relief Procedure, page 13 whe
you stop spraying and before cleaning, checking, ser-
vicing, or transporting equipment. Read warnings, 
page 3. 
F
IG
. 11
ti4836a
F
IG
. 12
Incorrect
Correct
ti4843a