Pressure Relief Procedure 
6
332161A
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever 
you see this symbol.
1.
Turn pressure control to lowest pressure.
2.
Hold gun against side of grounded metal flushing 
pail. Trigger gun to relieve pressure.
3.
Turn prime valve down. If you suspect spray tip or 
hose is clogged or pressure is not fully relieved, 
VERY SLOWLY loosen tip guard retaining nut or 
hose end coupling to relieve pressure. Then loosen 
completely. 
4.
Turn power switch OFF, if unit is being shut down or 
will be left unattended.
This equipment stays pressurized until pressure is 
manually relieved. To help prevent serious injury from 
pressurized fluid, such as skin injection, splashing 
fluid and moving parts, follow the Pressure Relief Pro-
cedure when you stop spraying and before cleaning, 
checking, or servicing the equipment.