Startup
332161A
9
Startup
1.
Turn pressure control to lowest pressure.
2.
Turn power ON.
3.
Increase pressure 1/4 turn to start motor. Allow fluid 
to circulate through drain tube for 15 seconds.
4.
Turn prime valve horizontal.Take spray gun trigger 
safety OFF.
5.
Hold gun against grounded metal flushing pail. Trig-
ger gun and flush 1 minute.
6.
Inspect for leaks. Do not stop leaks with hand or a 
rag! If leaks occur, perform Pressure Relief 
Procedure
, page 6. Tighten fittings. 
7.
Place siphon tube in paint pail.
8.
Trigger gun again into flushing pail until paint 
appears.
9.
Move gun to paint pail and trigger for 20 seconds. Set 
gun safety ON. 
10. Screw tip assembly onto gun. Tighten. For gun 
assembly instructions, see gun manual.