Graco 390 Classic Model 24U105 Manual De Usuario

Descargar
Página de 20
Startup 
14
332758A
Startup
1.
Turn pressure control to lowest pressure.
2.
Turn power ON.
3.
Increase pressure 1/4 turn to start motor. Allow fluid 
to circulate through drain tube for 15 seconds.
4.
Turn prime valve horizontal. Disengage trigger lock.
5.
Hold gun against grounded metal flushing pail. 
Trigger gun and flush 1 minute.
6.
Inspect for leaks. If leaks occur, perform Pressure 
Relief
, page 10. Tighten fittings. 
7.
Place siphon tube in paint pail.
8.
Trigger gun again into flushing pail until paint 
appears.
9.
Move gun to paint pail and trigger for 20 seconds. 
Engage trigger lock. 
10. Screw tip assembly onto gun. Tighten. For gun 
assembly instructions, see separate gun manual.
ti22222a
ON
OFF
ti5303a
1/4 turn
ti22223a
ti10167a
ti22221a
ti5310b
High-pressure spray is able to inject toxins into the 
body and cause serious bodily injury. Do not stop 
leaks with hand or rag.
TIA
ti5310c
ti5310e
ti2710a