Graco 312066z Manual De Usuario

Descargar
Página de 74
Models
312066Z
3
Models
E-20 SERIES
E-30 SERIES
E-XP1 SERIES
E-XP2 SERIES
* Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and mix 
chamber sizes may be less.
 Total system watts, based on maximum hose length for each unit:
E-20 and E-XP1 series, 210 ft (64 m) maximum heated hose length, including whip hose.
E-30 and E-XP2 series, 310 ft (94.5 m) maximum heated hose length, including whip hose.
 Maximum flow rate given for 60 Hz operation. For 50 Hz operation, maximum flow rate is 5/6 of 60 Hz maximum 
flow.
Part, Series
Full Load Peak 
Amps*
Voltage 
(phase)
System 
Watts†
Primary 
Heater 
Watts
Max Flow 
Rate
lb/min 
(kg/min)
Approximate 
Output per Cycle 
(A+B)
gal. (liter)
Maximum Fluid 
Working Pressure 
psi (MPa, bar)
259025, E
48
230V (1)
10,200
6,000
20 (9)
0.0104 (0.04)
2000 (14, 140)
259030, E
24
400V (3)
10,200
6,000
20 (9)
0.0104 (0.04)
2000 (14, 140)
259034, E
32
230V (3)
10,200
6,000
20 (9)
0.0104 (0.04)
2000 (14, 140)
Part, 
Series
Full Load Peak 
Amps*
Voltage 
(phase)
System 
Watts†
Primary 
Heater 
Watts
Max Flow 
Rate
lb/min 
(kg/min)
Approximate 
Output per Cycle 
(A+B)
gal. (liter)
Maximum Fluid 
Working Pressure 
psi (MPa, bar)
259026, F
78
230V (1)
17,900
10,200
30 (13.5)
0.0272 (0.1034)
2000 (14, 140)
259031, F
34
400V (3)
17,900
10,200
30 (13.5)
0.0272 (0.1034)
2000 (14, 140)
259035, F
50
230V (3)
17,900
10,200
30 (13.5)
0.0272 (0.1034)
2000 (14, 140)
259057, F
100
230V (1)
23,000
15,300
30 (13.5)
0.0272 (0.1034)
2000 (14, 140)
259058, F
62
230V (3)
23,000
15,300
30 (13.5)
0.0272 (0.1034)
2000 (14, 140)
259059, F
35
400V (3)
23,000
15,300
30 (13.5)
0.0272 (0.1034)
2000 (14, 140)
Part, Series
Full Load Peak 
Amps*
Voltage 
(phase)
System 
Watts†
Primary 
Heater 
Watts
Max Flow 
Rate
gpm (lpm)
Approximate 
Output per Cycle 
(A+B)
gal. (liter)
Maximum Fluid 
Working Pressure 
psi (MPa, bar)
259024, E
69
230V (1)
15,800
10,200
1.0 (3.8)
0.0104 (0.04)
2500 (17.2, 172)
259029, E
24
400V (3)
15,800
10,200
1.0 (3.8)
0.0104 (0.04)
2500 (17.2, 172)
259033, E
43
230V (3)
15,800
10,200
1.0 (3.8)
0.0104 (0.04)
2500 (17.2, 172)
Part, 
Series
Full Load Peak 
Amps* 
Voltage 
(phase)
System 
Watts†
Primary 
Heater 
Watts
Max Flow 
Rate
gpm (lpm)
Approximate 
Output per Cycle 
(A+B)
gal. (liter)
Maximum Fluid 
Working Pressure 
psi (MPa, bar)
259028, F
100
230V (1)
23,000
15,300
2.0 (7.6)
0.0203 (0.0771)
3200 (22, 220)
259032, F
35
400V (3)
23,000
15,300
2.0 (7.6)
0.0203 (0.0771)
3200 (22, 220)
259036, F
62
230V (3)
23,000
15,300
2.0 (7.6)