Graco 334466A Manual De Usuario

Descargar
Página de 59
Troubleshooting
334466A
33
Electrical
Symptom: Sprayer does not run, stops
running, or will not shut off.
13.
1.
Plug sprayer into correct voltage, 
grounded outlet.
2.
Turn the ON/OFF switch OFF wait 30 
seconds and then turn power back ON 
again (this ensures sprayer is in normal 
run mode).
3.
Turn pressure control knob clockwise 
1/2 turn.
4.
View digital display or remove control 
box cover to view control board status 
light. To determine which code (or any 
other code besides voltage supply) refer 
to the control board status light. Turn the 
ON/OFF switch OFF, remove the control 
cover then turn power back ON. Observe 
the status light. Blinking LED total count 
equals the error code (for example: two 
blinks equals CODE 02).
Keep clear of electrical and moving parts 
during troubleshooting procedures. To 
avoid electrical shock hazards when 
covers are removed for troubleshooting, 
wait 7 seconds after disconnecting power 
cord for stored electricity to dissipate.
Problem
What to Check
How to check
Sprayer does not run at all
AND
Display is blank
OR
Control board status light never lights
See flow chart, page 39.
Sprayer does not shut off
AND
Display shows E=02
OR
Control board status light blinks 2 
times repeatedly
Control board.
Replace control board.