Installation 
10
310649C
Connecting airline and 
accessories
1.
On each gun air supply line, install an air pressure 
regulator. 
It is recommended that the tip clean off air, gun 
actuation, and gun deactuation air be supplied 
and regulated separately.
A minimum of 80 psi (.55 mpa, 5.5 bar) air pres-
sure must be supplied to the gun for proper 
operation.
A three-way air valve, which exhausts cylinder 
air, is required.
2.
On each gun air supply line, install a bleed-type air 
shut off valve down stream of the gun air regulator.
3.
On the main air line, install a bleed-type air shut off 
valve.
Clean off air
Three 1/8 in. - 
27 npt ports 
(air inlet)
Gun 
deactuation
Gun 
actuation
ti4751b