XM Setup and Troubleshooting Guide
313289S
19
XM Setup and Troubleshooting Guide
The following setup information will help ensure the system is setup properly. See the XM repair-parts manual for trouble-
shooting and repair instructions.
Grounding
Ground system to a true earth ground.
Ensure incoming power is grounded.
Air Supply
Use at least a 3/4 in. (19mm) ID air hose, no longer 
than 50 feet (15m).
Ensure the first gauge (supply) stays above 80 psi 
(0.55 MPa, 5.5bar) while spraying.
Ensure that the pump spray pressure regulator is set to 
at least 35 psi (2.4 bar) for spraying.
Ensure that the solenoid air filter/regulator behind the 
air panel is set to at least 80-85 psi.
Check that the air filter element in the solenoid air fil-
ter/regulator behind the air panel is clean.
Calibration
Adjust the B side fluid restrictor so that the calibration 
bar graph averages center to right middle. This means 
that the “B” dosing valve is open 25% to 75% of the 
time.
Ensure dosing valve needle packing nuts are not 
adjusted too tight. They should be snug when there is 
no fluid pressure on the valve.
If feed pumps are used, don’t use more than 250psi 
(17 bar). Excess pressure adds double the amount of 
pressure on only the upstroke of the XM metering 
pump.
Motor Icing
Air motors accumulate ice in the exhaust valving and muf-
fler under hot and humid conditions or under cold ambient 
conditions. It can cause pressure loss or motor stalling. 
The ‘B’ fluid pressure should always be 15% to 30% 
higher than ‘A’ pressure.
A larger pressure difference indicates ‘A’ motor icing.
A smaller or negative pressure difference indicates ‘B’ 
motor icing.
Ensure that the NXT motor De-Ice bleed valves are 
open to bleed warm air across the ice.
Ensure that the motor is left active when not spraying 
to keep the internal bleed air working. Leave the motor 
active in Spray mode or Manual mode to keep the 
bleed air on.
Restrictions or Lost Pressure
Always use filter screens in the XM pump lowers. Filter 
style pumps come with 60 mesh screens. Optional 30 
mesh elements are also supplied.
Always use a gun filter. 60 mesh is provided in the gun. 
Check that the static mixer is clean.
Early mix manifolds (2009) had a 40 mesh screen on 
the B side. The screen could plug with materials that 
have filled ‘B’ side fluids.
Remote Mix Manifold Applications
Ensure remote mix manifold outlet kit is installed. See XM 
Repair parts manual. The kit includes outlet check valves 
which isolate the pump pressure sensors from the outlet 
hoses, and includes a ‘B’ side restrictor valve for the 
machine outlet.
NOTE: Early remote manifold machines didn’t include 
the ‘B’ restrictor valve from the factory.
Ensure that the ‘A’ and ‘B’ outlet hose sizes volume 
balanced close to the mix ratio. Unbalanced hose sizes 
can cause off ratio slugs at the mix manifold during 
pressure and/or flow transitions. See XM Mix Manifold 
Kits manual.
If a minimum of integration and mix hose is used, 
ensure that “Fast Dosing” is selected in the setup 
screens.
Software Version
Ensure all modules in the system use software from 
same token. Different software versions may not be 
compatible.
The latest software version for each system can be 
found at Tech Support at www.graco.com.