Graco 313289s Manual De Usuario

Descargar
Página de 86
Alarms 
24
313289S
Alarm Codes and Troubleshooting
Alarm 
Code
Alarm Problem
When Active
Cause
Solution
General Performance Alarms
R4B
Ratio High B (Overdose B), 
system delivering too much B 
component.
Spray
B Dosing valve not closing.
Perform Pump Test to test for 
leakage. See Pump and Meter-
ing test in manual 312359.
Loosen valve packing nut.
Check air signal at valve top
Repair valve or air solenoid. 
See Replace Solenoid Mod-
ule
, page 32
.
No B restriction at mix manifold. Increase B Restriction by turn-
ing B restrictor stem clockwise. 
See Adjust B Mix Manifold 
Restriction in manual 312359.
Pump filter plugged on A side.
Clean filter. See manual 
311762.
Use alternate 30 mesh screen. 
See manual 311762 for part 
number.
Inlet air dropping below 80 psi 
(0.55 MPa, 5.5 bar) while spray-
ing. B dosing valve not closing 
correctly.
Check air filters. See Air Con-
trols
, page 40.
Use larger air hose.
Use larger compressor.
Use smaller gun tips or less 
guns to reduce flow rate.
Solenoid air regulator set below 
80 psi (0.55 MPa, 5.5 bar)
Adjust air regulator.
R1B
Ratio Low B (under dose B); 
system delivering not enough 
B component.
Spray
B dosing valve will not open.
Check for air signal to valve.
B mix manifold valve closed.
Open green mix manifold valve.
Pump filter plugged on B side.
Use alternate 30 mesh screen. 
See manual 311762 for part 
number.
Clean B pump outlet filter. See 
manual 311762.
REC
System detected five R4B 
(ratio high B) or five R1B 
(ratio low B) alarms within five 
minutes. Sprayer shuts down 
for five minutes to resolve 
problem.
Spray
See R4B or R1B alarm causes. See R4B or R1B alarm solu-
tions. Flush mixed material if 
necessary, and purge off-ratio 
mixed material in hose.
FHA 
FHB
System detects pump move-
ment (fluid flow) when valves 
are closed.
Spray
Recirculation valve or dosing 
valve open or leaking for more 
than 5 seconds.
Close or repair recirculation 
valve, and run Pump Test. See 
Pump and Metering test in man-
ual 312359. See Mix Manifold 
Assembly
, page 42.
R2D
Dosing sizes are not opti-
mized.
Spray
Dosing valve is operating near 
high or low timing limits.
Adjust mix manifold B restrictor 
stem clockwise or counter 
clockwise as indicated by bar 
graph on restrictor screen. See 
Adjust B Mix Manifold Restric-
tion in manual 312359.