Overview
Isocyanate Hazard
Material Self-Ignition
Moisture Sensitivity of 
Isocyanates
Isocyanates (ISO) are catalysts used in two component 
foam and polyurea coatings. ISO will react with moisture 
(such as humidity) to form small, hard, abrasive crystals, 
which become suspended in the fluid. Eventually a film 
will form on the surface and the ISO will begin to gel, 
increasing in viscosity. If used, this partially cured ISO 
will reduce performance and the life of all wetted parts.
NOTE: 
The amount of film formation and rate of crystallization 
varies depending on the blend of ISO, the humidity, and 
the temperature.
To prevent exposing ISO to moisture:
Always use a sealed container with a desiccant 
dryer in the vent, or a nitrogen atmosphere. Never 
store ISO in an open container.
Keep the ISO lube pump reservoir filled with Graco 
Throat Seal Liquid (TSL), Part 206995. The lubri-
cant creates a barrier between the ISO and the 
atmosphere.
Use moisture-proof hoses specifically designed for 
ISO, such as those supplied with your system.
Never use reclaimed solvents, which may contain 
moisture. Always keep solvent containers closed 
when not in use.
Never use solvent on one side if it has been con-
taminated from the other side.
Always park pumps when you shutdown.
Always lubricate threaded parts with Part 217374 
ISO pump oil or grease when reassembling.
XM sprayers are not approved for use in hazardous 
locations unless the base model, all accessories, all 
kits, and all wiring meet local, state, and national 
codes. See Models, page 7, to determine the appro-
priate location for your particular model.
Spraying materials containing isocyanates creates 
potentially harmful mists, vapors, and atomized partic-
ulates.
Read material manufacturer’s warnings and material 
MSDS to know specific hazards and precautions 
related to isocyanates.
Prevent inhalation of isocyanate mists, vapors, and 
atomized particulates by providing sufficient ventila-
tion in the work area. If sufficient ventilation is not 
available, a supplied-air respirator is required for 
everyone in the work area.
To prevent contact with isocyanates, appropriate per-
sonal protective equipment, including chemically 
impermeable gloves, boots, aprons, and goggles, is 
also required for everyone in the work area.
Some materials may become self-igniting if applied 
too thick. Read material manufacturer’s warnings and 
material MSDS.