Prime Empty System
3A0420T
25
Recirculate Prior to Spraying or 
Re-Prime After a Pump Runs Dry
NOTE: Agitate, recirculate, and heat the material 
only as necessary to avoid mixing air into the fluid.
Use the recirculation mode when heating the material is 
required. Note the temperature at the top of the heater 
(outgoing or back to the hopper). When the thermome-
ter reaches operating temperature, the material is ready 
to spray.
If using a system that does not require heat, recircula-
tion is still required prior to spraying. Recirculation 
ensures that any settled fillers are mixed in, the pump 
lines are fully primed, and the pump check valves are 
operating smoothly.
Recirculation also allows you to re-prime one side that 
has run dry.
1.
Follow 
2.
Close the dual shutoff handle (AE).
3.
Ensure the recirculation hoses (U) are in the correct 
hoppers (J).
4.
Open the circulation valve handle (AC).
5.
Turn down the air pressure regulator (CB) and then 
open the main air shutoff valve (CA). Use the air 
pressure regulator to slowly increase the air pres-
sure to the pumps until they start running slowly.
6.
Run the pumps for a few minutes or until the mate-
rial has reached the desired temperature. See 
7.
Close the main air shutoff valve (CA).
8.
Se
Spray, page 26.
Heat Fluid
To heat fluid evenly throughout the system:
1.
Circulate the fluid at approximately 1/2 gpm 
(10-20 cycles/min.) to raise the temperature of the 
hoppers to 80-90° F (27-32° C).
2.
Decrease the circulation rate to approximately 
0.25 gpm (5 cycles/min.) to increase the heater out-
let temperature to match the spray temperature.
NOTE: Circulating the fluid too quickly without 
decreasing the circulation rate will increase only the 
hopper temperature. Similarly, circulating fluid too 
slowly will increase only the heater outlet tempera-
ture.