Empty and Flush Entire System (new system or end of job)
3A0420T
29
Empty and Flush Entire System
(new system or end of job)
NOTE: 
If the system includes heaters and heated hose, 
turn them off and allow to cool before flushing. 
Do not turn on the heaters until the fluid lines 
are clear of solvent.
Cover fluid containers and use the lowest possi-
ble pressure when flushing to avoid splashing.
Before color change or shutdown for storage, 
circulate the solvent at a higher flow rate and for 
a longer time. Change the solvent when it gets 
dirty.
To only flush the fluid manifold, see Flush Mix 
Manifold, Hose, and Spray Gun, pa
ge 28.
If the machine is inoperable, use drain plugs on 
the pump inlet fittings.
Guidelines
Flush new systems if the coating materials will be con-
taminated by mineral oil.
Flushing will help prevent materials from settling or gell-
ing in the pumps, lines, and valves. Flush the system 
when any of the following situations occur.
anytime the system will not be used for more 
than one week (depending on materials used)
if the materials used have fillers that will settle
if using materials that are moisture sensitive
before servicing
if the machine is going into storage, replace the 
flush solvent with light oil. Never leave the 
equipment empty of any fluid.
Procedure
1.
Follow 
2.
Engage the trigger lock. Turn the main pump air 
regulator (CB) fully counter-clockwise to shut off.
3.
Move the recirculation lines (U) to separate fluid 
containers to pump remaining fluid out of the sys-
tem.
4.
Open the circulation handle (AC). See F
. 2 on 
page 15.
5.
Increase the main pump air regulator (CB) pressure 
to 20 psi (138 kPa, 1.38 bar).
6.
Open the main air shutoff valve (CA).
NOTE: If the system does not start with static pres-
sure, increase the air pressure by 5 psi (35 kPa, 
0.35 bar) increments. To avoid splashing, do not 
exceed 35 psi (241 kPa, 2.4 bar).
CB
TI1949a
r_571100_3A0420A_11a-1
U
CA
CB