Graco 3A0420T Manual De Usuario

Descargar
Página de 64
Repair 
38
3A0420T
Mix Manifold Assembly
1.
Follow 
2.
Disconnect the fluid hose (25) and the flush hose 
from the mix manifold (36).
3.
Loosen the union fittings (306) that connect to the 
mix manifold adapter fittings.
4.
Remove the mix manifold assembly (36).
5.
See mix manifold manual for service and repair 
instructions.
Fluid Circulation Manifold with 
Over Pressure Relief Valves
See F
1.
Flush before repairing equipment, if possible. See 
Empty and Flush Entire System (new system or 
end of job)
, page 29.
2.
Follow 
3.
Disconnect all fluid hoses from the fluid circulation 
manifold (35).
4.
Remove the mix manifold if it is assembled to the 
fluid circulation manifold. See 
Assembly for instructions.
5.
Loosen the two screws (37) that secure the manifold 
(35) to the cart (1).
6.
Remove the two screws (37) and fluid circulation 
manifold (35) from the cart (1).
Replace Over Pressure Relief Valves
1.
Flush before repairing equipment, if possible. See 
Empty and Flush Entire System (new system or 
end of job)
, page 29.
2.
Follow 
3.
Ensure handle (312) is in the down position. 
Remove the screws (313), jam nut (304), handles 
(311), handle rod (312), clips (318), and 
springs (320).
4.
Unscrew both over pressure relief valves (302) from 
the manifold.
NOTE: The correct over pressure relief valve must be 
used on all systems. Choose the correct color coded 
valve from the chart on page 39.
5.
Apply blue threadlock to new over pressure relief 
valves (302) and install in the manifold. Torque to 
28-32 ft-lb (38-43 N•m).
6.
Place a spring (320) over each valve stem. Place a 
clip (318) in each valve stem groove to retain the 
springs.
36
306
r_571101_3a0420a_38a
F
IG
. 11: Fluid Circulation Manifold
37
35
1
r_571101_3a0420a_39a
312
311
313
302
302
318
318
r_258988_3a0420a_2b
311
313
304
320
302
320
304