Graco ti13585a Manual De Usuario

Descargar
Página de 44
Service
313516G
25
Reassembly
1. Non-circulating guns only: Lubricate the 
backup ring (20†) and o-ring (21†) and 
install them on the fluid outlet port plug 
(19). Install the plug in the fluid outlet port 
of the fluid housing (2). See F
2. All guns: Reinstall the gasket (22) in the 
fluid housing (2).
3. Install the o-rings (8*, 9*) on the piston (3). 
Install the two o-rings (10*, 11*) on each of 
the piston stems (T). Lubricate all the 
o-rings, the piston, and the piston stems.
4. Remove the protective paper from the 
sticky side of the gasket (12*) and adhere 
the gasket to the bottom of the piston hous-
ing (1), making sure the three holes in the 
gasket are properly aligned with the match-
ing holes in the housing.
5. Lubricate the washers (45†) and spacer 
(46†). Insert them into the packing nut (16) 
as shown in F
. 20, The step on the 
spacer faces into the packing nut.
6. Insert the packing nut into the fluid housing 
(2) and torque to 95-105 in-lb (10.7-11.8 
N•m).
7. Align the gasket (15*) as shown in the 
exploded view in F
. 21. Place the gasket 
on the piston housing (1), then install the 
fluid housing (2) onto the piston housing. 
Torque the two screws (14) to 35-45 in-lb 
(4.0-5.1 N•m).
a. Insert the piston (3) into the piston 
housing (1).
b. Ensure nozzle sealing o-ring (36) is 
installed on nozzle (23).
8. To avoid galling of the fluid nozzle seat in 
the fluid housing, apply a thin film of lubri-
cant to the threads. Install the nozzle into 
the fluid housing. Torque the nozzle 
securely to 35-45 in-lb (4.0-5.1 N•m).
NOTE: If you are replacing the needle tip (5a), 
apply semi-permanent anaerobic sealant to 
two threads at the end of the needle shaft. 
Assemble the needle tip to the shaft and hand 
tighten. Allow adequate time for the sealant to 
cure before installing the needle assembly into 
the gun.
9. Lubricate and install the needle (5) into the 
back of the gun assembly. Push it straight 
in through the piston.
10. Install the needle stop (29) on the needle. 
Coat the setscrew (30) with semi-perma-
nent anaerobic sealant and install the 
screw into the needle stop. Torque to 
6.5-7.5 in-lb (0.73-0.85 N•m). Pull on the 
needle to make sure it seats fully.
11. Install the springs (6, 7).
12. Lubricate the threads of the piston housing 
(1). Screw the cap (4) onto the housing 
until it bottoms out.
13. Install the air cap (24) and air cap retainer 
(25).
14. Reinstall the gun on the manifold using the 
four screws (13). Start the threads of all 
four screws. Tighten the front two screws 
first, and then tighten the back two. Torque 
all four screws evenly to 65 in-lb (7.3 N•m).
F
IG
. 20. Fluid packings
45
46
45
16
ti17603a