Graco ti13586a Manual De Usuario

Descargar
Página de 44
Installation 
10
313516G
Installation
The Automatic AirPro spray gun can spray 
most coatings or finishes currently being used 
for automotive, industrial, aerospace, marine, 
wood, plastic and architectural applications, 
while easily operating from paint delivery sys-
tems, such as pressure pots or remote pumps 
for production line operation.
The air regulator must have a minimum air flow 
capacity of 30 scfm at 100 psi (0.7 MPa, 7.0 
bar) air pressure. 
Ventilate Spray Booth
Check and follow all national, state, and 
local codes regarding air exhaust velocity 
requirements.
Check and follow all local safety and fire 
codes.
Configure Gun and Manifold
The gun is supplied with an internal fluid plug 
and seals (19, 20, 21). To use the gun in a cir-
culating system, remove the internal plug. In a 
non-circulating system, leave the plug in place 
to minimize flush time.
Circulating System 
1. Apply anti-seize lubricant to the threads 
and mating faces of the manifold (101) and 
the elbows (107), supplied unassembled.
2. Install the elbows (107) in both fluid ports of 
the manifold (101).
3. Connect the fluid supply line to one elbow 
and the fluid return line to the other. The 
manifold fluid ports are reversible.
4. Install the gun on the manifold, using the 
four screws (13). Start the threads of all 
four screws. Tighten the front two screws 
first, and then tighten the back two. Torque 
all four screws evenly to 65 in-lb (7.3 N•m).
Non-circulating System
1. See F
. 1. Apply anti-seize lubricant to the 
threads and mating faces of the manifold 
(101), plug (109), and elbow (107), sup-
plied unassembled.
2. Install an elbow (107) in one fluid port of 
the manifold (101), and a plug (109) in the 
other port.
3. Install the internal plug (19) in the gun fluid 
port on the same side as the manifold plug. 
4. Connect the fluid supply line to the fluid 
inlet elbow (107).
5. Install the gun on the manifold, using the 
four screws supplied. Start the threads of 
all four screws. Tighten the front two 
screws first, and then tighten the back two. 
Torque all four screws evenly to 65 in-lb 
(7.3 N•m).
F
IG
. 1: Non-Circulating Setup Shown (cutaway view)
Remove when used in circulating systems.
1
ti8587b
1
Replace with elbow (107) when used in 
circulating systems.
2
2
19
101
107
109
21
20