Spray Adjustments 
22
312062W
Cycle Count Key/LED
Press 
 to display cycle count.
Hydraulic Pressure Control 
Knob
Use to adjust hydraulic pressure available to 
the hydraulic drive system. Turn knob (HC) 
clockwise to increase pressure and counter-
clockwise to decrease pressure. Use hydraulic 
pressure gauge (HP, page 17) to view hydrau-
lic pressure.
Motor Control Arrow Keys
Use  
or  
to:
Adjust pressure imbalance settings, page 
33.
Adjust standby settings, page 37.
Spray Adjustments
Flow rate, atomization, and amount of over-
spray are affected by four variables.
Fluid pressure setting. Too little pressure 
results in an uneven pattern, coarse droplet 
size, low flow, and poor mixing. Too much 
pressure results in excessive overspray, 
high flow rates, difficult control, and exces-
sive wear.
Fluid temperature. Similar effects to fluid 
pressure setting. The A and B tempera-
tures can be offset to help balance the fluid 
pressure.
Mix chamber size. Choice of mix chamber 
is based on desired flow rate and fluid vis-
cosity.
Clean-off air adjustment. Too little 
clean-off air results in droplets building up 
on the front of the nozzle, and no pattern 
containment to control overspray. Too 
much clean-off air results in air-assisted 
atomization and excessive overspray.
To clear counter, press and hold 
 
for 3 sec.
Component A and B outlet pressures 
will be higher than the hydraulic set 
pressure, depending on the model (see 
Pressure Ratio dataSystems, page 3)
Component A and B pressure may be 
viewed on the pressure gauges (GA, 
GB), or the higher of the two pressures 
may be displayed on the motor control 
panel (MC). See F
+
-
ti7731a
ti7732a