Graco H50 Manual De Usuario

Descargar
Página de 52
Startup 
30
312062W
Startup
1. Check generator fuel level. 
Running out of fuel will cause voltage fluc-
tuations that can damage electrical equip-
ment.
2. Ensure the main breaker on the genera-
tor is in the off position.
3. Start the generator. Allow it to reach full 
operating temperature.
4. Close the bleed valve on the air com-
pressor.
5. Switch on the air compressor starter 
and air dryer, if included.
6. Turn on power to the Reactor.
7. Load fluid with feed pumps
a. Check that all Setup steps are com-
plete.
b. Check that inlet screens are clean 
before daily startup, page 45.
c. Check level and condition of ISO lube 
daily, page 44.
d. Turn on component B agitator, if used.
e. Turn both PRESSURE RELIEF/SPRAY 
valves (SA, SB) to SPRAY 
.
f.
Start feed pumps.
g. Open fluid inlet valves (FV). Check for 
leaks.
NOTICE
Proper system setup, startup, and shutdown 
procedures are critical to electrical equip-
ment reliability. The following procedures 
ensure steady voltage. Failure to follow 
these procedures will cause voltage fluctua-
tions that can damage electrical equipment 
and void the warranty.
Do not operate Reactor without all covers 
and shrouds in place. 
The Reactor is tested with oil at the fac-
tory. Flush out the oil with a compatible 
solvent before spraying. See page 47.
ti9877a
SA
SB
FV
ti10002a