Fluid Circulation 
40
312062W
Fluid Circulation
Circulation Through Reactor
To circulate through gun manifold and preheat 
hose, see page 41.
1. Follow Startup procedures, page 30.
page 14. Route circulation lines back to 
respective component A or B supply drum. 
Use hoses rated at the maximum working 
pressure of this equipment. SeTechnical 
Data
, pa
ge 49.
3. Set PRESSURE RELIEF/SPRAY valves 
(SA, SB) to PRESSURE RELIEF/CIRCU-
LATION .
4. Turn main power ON 
.
5. Set temperature targets, see page 31. Turn 
on 
 and 
 heat zones by pressing 
Do not turn on 
 heat zone 
unless hoses are already loaded with fluid.
6. Press 
 to display actual temperatures.
7. Before starting motor, reduce hydraulic 
pressure to the minimum required to circu-
late fluid until 
 and 
 tempera-
tures reach targets.
8. Press motor 
 to start motor and 
pumps. Circulate fluid at lowest possible 
pressure until temperatures reach targets.
9. Turn on 
 heat zone by pressing 
.
Do not circulate fluid containing a blowing 
agent without consulting with your material 
supplier regarding fluid temperature limits. 
Do not install shutoffs downstream of the 
PRESSURE RELIEF/SPRAY valve outlets 
(BA, BB). The valves function as overpres-
sure relief valves when set to SPRAY 
Lines must be open so valves can automati-
cally relieve pressure when machine is oper-
ating.
ti9879a
SA
SB
A
B
A
B
-
ti7732a