Maintenance 
44
312062W
Maintenance
Inspect hydraulic and fluid lines for leaks 
daily.
Clean up all hydraulic leaks; identify and 
repair cause of leak.
Inspect fluid inlet strainer screens daily, 
see below.
Grease circulation valves weekly with 
Fusion grease (117773).
Inspect ISO lubricant level and condition 
daily, see page 46. Refill or replace as 
needed.
Check hydraulic fluid level weekly. Check 
hydraulic fluid level on dipstick (DS). Fluid 
level must be between indent marks (IM) 
on dipstick. Refill as required with approved 
hydraulic fluid; see Technical Data on 
page 49 and the Approved Anti-Wear 
(AW) Hydraulic Oils
 table in the Reactor 
Repair-Parts manual 312063. If fluid is dark 
in color, change fluid and filter.
Change break-in oil in a new unit after first 
250 hours of operation or within 3 months, 
whichever comes first. See Table 4 for rec-
ommended frequency of oil changes 
Table 4: Frequency of Oil Changes
Keep component A from exposure to mois-
ture in atmosphere, to prevent crystalliza-
tion.
Clean gun mix chamber ports regularly. 
See gun manual.
Clean gun check valve screens regularly. 
See gun manual.
Use compressed air to prevent dust buildup 
on control boards, fan, motor (under 
shield), and hydraulic oil coolers.
Keep vent holes on bottom of electrical 
cabinet open.
ti9879a
S
DS
ti10003a
ti7861a
IM
Ambient 
Temperature
Recommended 
Frequency
0 to 90°F
(-17 to 32°C)
1000 hours or 12 
months, whichever 
comes first
90°F and above
(32°C and above)
500 hours or 6 months, 
whichever comes first