1. Locate Reactor
a. Locate Reactor on a level surface. See 
Dimensions, page 48, for clearance 
and mounting hole dimensions.
b. Do not expose Reactor to rain.
c. Use the casters to move Reactor to a 
fixed location, or bolt to shipping pallet 
and move with forklift.
d. To mount on a truck bed or trailer, 
remove casters and bolt directly to truck 
or trailer bed. See page 48.
2. General equipment guidelines
Determine the correct size generator. 
Using the correct size generator and proper 
air compressor will enable the proportioner 
to run at a nearly constant RPM. Failure to 
do so will cause voltage fluctuations that 
can damage electrical equipment. Ensure 
the generator matches the voltage and 
phase of the proportioner.
Use the following procedure to determine 
the correct size generator.
a. List system components that use peak 
load requirements in watts.
b. Add the wattage required by the system 
components.
c. Perform the following equation:
Total watts x 1.25 = kVA (kilo-
volt-amperes)
d. Select a generator size that is equal to 
or greater than the determined kVA.
Use proportioner power cords that meet or 
exceed the requirements listed in Table 2. 
Failure to do so will cause voltage fluctua-
tions that can damage electrical equip-
ment.
Use an air compressor with constant speed 
head unloading devices. Direct online air 
compressors that start and stop during a 
job will cause voltage fluctuations that can 
damage electrical equipment.
NOTICE
Proper system setup, start up, and shutdown 
procedures are critical to electrical equip-
ment reliability. The following procedures 
ensure steady voltage. Failure to follow these 
procedures will cause voltage fluctuations 
that can damage electrical equipment and 
void the warranty.
NOTICE
To prevent damage from tipping over and fall-
ing, proper care needs to be taken when lift-
ing the Reactor. Bolt Reactor to original 
shipping pallet, to keep stable, before lifting.