Standby
312062W
37
Standby
If you stop spraying for a period of time, the 
unit will enter standby by shutting down the 
electric motor and hydraulic pump, to reduce 
equipment wear and minimize heat buildup. 
The ON/OFF LED and the pressure/cycle dis-
play on the motor control panel will flash when 
in standby.
To restart, spray off target for 2 sec. The sys-
tem will sense the pressure drop and the motor 
will ramp up to full speed in a few seconds.
To activate or disable standby, adjust DIP 
switch #3 on the motor control board. See 
Reactor Repair-Parts manual 312063.
The idle time before entering standby is 
user-settable as follows:
1. Turn main power switch OFF 
.
2. Press and hold 
, then turn main power 
switch ON 
.
3. Press 
 or 
 to select desired timer 
setting (5-20, in 5 minute increments). This 
sets the length of inactive time before the 
unit will enter standby.
4. Turn main power switch OFF 
 to 
save changes.
The , , 
and  
heat 
zones 
will not be shut off in standby.
This feature is disabled from the factory.