Installation
3A0732J
7
Installation
Prepare the Operator
All persons who operate the equipment must be trained 
in the safe, efficient operation of all system components 
as well as the proper handling of all fluids. All operators 
must thoroughly read all instruction manuals, tags, and 
labels before operating the equipment.
Prepare the Site
Ensure that you have an adequate compressed air
supply.
Bring a compressed air supply line from the air com-
pressor to the pump location. Be sure all air hoses are 
properly sized and pressure-rated for your system. Use 
only electrically conductive hoses. The air hose should 
have a 3/8 npt(m) thread. A quick disconnect coupling is 
recommended. 
Keep the site clear of any obstacles or debris that could 
interfere with the operator's movement.
Have a grounded, metal pail available for use when 
flushing the system.
Supplied Components
See F
The red-handled bleed-type master air valve (D) 
is required in your system to relieve air trapped 
between it and the air motor and gun when the valve 
is closed. Do not block access to the valve.
The pump air regulator (F) controls pump speed 
and outlet pressure by adjusting the air pressure to 
the pump.
The air pressure relief valve (P) opens automati-
cally to prevent overpressurization of the pump. 
The gun air regulator (E) adjusts the air pressure 
to the air-assisted spray gun.
The spray gun (H) dispenses the fluid. The gun 
houses the spray tip (not shown), which is available 
in a wide range of sizes for different spray patterns 
and rates of flow. Refer to gun manual for tip instal-
lation. 
The red
 
hose (G) provides the gun air supply.
The blue hose (K) provides the gun fluid supply. 
The suction kit with strainer (J) allows the pump 
to draw fluid from a 5 gallon (19 liter) pail. 
Inline Fluid Filter Kits
Inline fluid filter kits are available as an accessory in 
stainless steel (24F271) or aluminum (24F272), to filter 
particles from fluid as it leaves the pump. Kits include a 
60 mesh (250 micron) stainless steel element.
Air Line Accessories
Install the following accessories in the order shown in 
F
. 2, using adapters as necessary.
An air-line filter (C) removes harmful dirt and mois-
ture from the compressed air supply.
A second bleed-type air shutoff valve (B) isolates 
the air line accessories for servicing. Locate 
upstream from all other air line accessories.