Graco 16N654 Manual De Usuario

Descargar
Página de 44
Operation 
12
3A2308C
Setup
Starting a New Job
1.
Engage trigger lock. 
2.
Install liner into cup and fill liner 1/2 full with appro-
priate cleaning fluid for material about to be 
sprayed. 
3.
Thread lid onto cup and connect cup to sprayer. 
4.
Put prime/pressure relief valve in UP position. 
NOTE: After storage, the piston seals need to be 
energized prior to next use to prevent leakage. To 
energize, follow steps below:
a.
Prime system with flushing fluid.
b.
Spray at low pressure setting “1” for 10 sec-
onds. 
c.
Drain fluid. You are now ready to spray.
5.
You MUST set pressure control to setting “1”.
6.
Disengage trigger lock, turn sprayer upside-down 
and trigger for approximately 5 seconds to recircu-
late material. 
Flammable fumes (such as solvent and paint fumes) in 
work area can ignite or explode.
See Grounding Instructions, page 3.
Do not spray flammable or combustible liquids in a con-
fined area.
Keep spray area well-ventilated. Keep a good supply 
of fresh air moving through the area.
NOTICE
Your sprayer is NOT compatible with harsh cleaners 
such as chlorine bleach. Using these cleaners will 
cause damage to the sprayer. 
NOTICE
Always flush any cleaning material from the previous 
use before starting a new job. If the new spraying 
material is not compatible with leftover material in the 
pump, adverse reactions could ruin new material. 
NOTICE
Do NOT spray zinc coatings or materials with 
aggregate. Accelerated pump wear will occur.
ti19350a
ti19348a
ti19384a
ti19354a
ti19347a
ti19374a