Repair 
30
3A2308C
Pressure Control Knob 
Removal
1.
Engage trigger lock and put prime/pressure relief 
valve in UP position to relieve pressure. 
2.
Loosen two set screws (34) from pressure control 
knob and remove knob.
Installation
NOTE: Inlet valve must be fully installed before outlet 
valve can be installed. 
1.
Make sure prime/pressure relief valve is in UP posi-
tion. Use a thin screwdriver or allen wrench to turn 
outlet valve counter-clockwise until it touches inlet 
ball. DO NOT TIGHTEN. Outlet valve should only 
be threaded until inlet ball does not move when 
touched. 
2.
Install pressure control knob. Turn knob fully coun-
ter-clockwise (“0” setting will line up with red dot). 
Torque set screws (34) to 40 in-lb (4.5 N•m).
ti19350a
ti19347a
ti19620a
34
ti19347a
ti19616a
ti19351a
ti19620a
34