Graco 16N654 Manual De Usuario

Descargar
Página de 44
Operation 
8
3A2308C
Sprayer Status Indicator
*NOTE: The sprayer status indicator light is visible for 10 seconds after the trigger is released.
No light
Normal operation.
No action required.
Solid Red
Battery is too hot. Unit will 
shut down until battery has 
cooled. 
Change battery.
Allow battery to cool.
Liquid has contacted control 
board. 
Allow unit to dry.
Flashing Red
Motor is too hot and will shut 
down if heavy use continues. 
Unit will shut down until motor 
has cooled. 
Increase tip size.
Turn down pressure.
Let unit cool down.
Solid Yellow
Battery is low or 
battery is too cold.
Charge battery.
Warm up battery.
Flashing Yellow
High pressure signal. Gun will 
shut down after 1.5 seconds.
Turn pressure control 
counter-clockwise to reduce 
pressure. 
Increase tip size.
Material is too thin--do not thin 
as much.
Solid red and solid yellow Locked motor.
Bring sprayer in to service cen-
ter for diagnostics.
ti19361a
Red
Yellow